A 0.85% saline as alternative detection buffer for SD-Bioline HIV rapid test in resource limited setting

By: Contributor(s): Material type: TextTextPublisher number: Phone: +255 28 298 3384 Fax: +255 28 298 3386 Email: vc@bugando.ac.tz Website: www.bugando.ac.tz Language: English Series: ; The Pan African Medical Journal Volume 37 Publication details: Mwanza, Tanzania: African Field Epidemiology Network & Catholic University of Health and Allied Sciences [CUHAS – Bugando] 2020 Online resources: Summary: Abstract: Accuracy in the diagnosis is a key step to identify HIV infected individuals for appropriate management. Insufficient supply of manufacturer´s buffers in relation to the number of strips per kit has negative impact on patient´s results hence improper patient´s management. In resource limited settings, some laboratory staff use different substitute buffers which has never been validated on their reliability. This study aimed at comparing the performance of 0.85% saline and SD-Bioline manufacturer´s buffer in detection of HIV antibodies. A total of 220 whole blood specimens: 110 HIV positive specimens from patients attending care and treatment center (CTC) and 110 HIV negative specimens from blood donors were re-tested for HIV status using SD-Bioline HIV rapid test using manufacturer´s buffer and 0.85% saline separately. Data and laboratory results were recorded in Microsoft excel sheet followed by analysis using STATA version 13. For all tested samples, the level of agreement between 0.85% saline and manufacturer´s buffer was 98.64% (kappa=0.9727). The value of kappa indicates very good agreement between 0.85% saline and manufacturer´s buffer. In incidents where manufacturer´s buffer is not sufficient, 0.85% saline can give reliable results. Further studies to evaluate the suitable buffer for other rapid tests for HIV and other diseases are recommended especially in resource limited settings.
Item type: RESEARCH ARTICLES
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Total holds: 0

Abstract:

Accuracy in the diagnosis is a key step to identify HIV infected individuals for appropriate management. Insufficient supply of manufacturer´s buffers in relation to the number of strips per kit has negative impact on patient´s results hence improper patient´s management. In resource limited settings, some laboratory staff use different substitute buffers which has never been validated on their reliability. This study aimed at comparing the performance of 0.85% saline and SD-Bioline manufacturer´s buffer in detection of HIV antibodies. A total of 220 whole blood specimens: 110 HIV positive specimens from patients attending care and treatment center (CTC) and 110 HIV negative specimens from blood donors were re-tested for HIV status using SD-Bioline HIV rapid test using manufacturer´s buffer and 0.85% saline separately. Data and laboratory results were recorded in Microsoft excel sheet followed by analysis using STATA version 13. For all tested samples, the level of agreement between 0.85% saline and manufacturer´s buffer was 98.64% (kappa=0.9727). The value of kappa indicates very good agreement between 0.85% saline and manufacturer´s buffer. In incidents where manufacturer´s buffer is not sufficient, 0.85% saline can give reliable results. Further studies to evaluate the suitable buffer for other rapid tests for HIV and other diseases are recommended especially in resource limited settings.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Catholic University of  Health and Allied Sciences - CUHAS
Directorate of ICT @ 2024