Local cover image
Local cover image
Image from Google Jackets

Diagnostic Performance of Kato Katz Technique and Point-of-Care Circulating Cathodic Antigen Rapid Test in Diagnosing Schistosoma mansoni Infection in HIV-1 Co-Infected Adults on the Shoreline of Lake Victoria, Tanzania

By: Contributor(s): Material type: TextTextPublisher number: Phone: +255 28 298 3384 Fax: +255 28 298 3386 Email: vc@bugando.ac.tz Website: www.bugando.ac.tz Language: English Series: ; Tropical medicine and infectious disease Volume 3 Issue 2Publication details: Mwanza: MDPI & Tanzania Catholic University of Health and Allied Sciences [CUHAS – Bugando] 29 May 2018Description: Pages 54Online resources: Summary: Abstract Background: The diagnostic performance of the Kato Katz (KK) technique and the point-of-care circulating cathodic antigen (POC-CCA) test in detecting S. mansoni infection in the presence of the human immunodeficiency virus-1 (HIV-1) infection has remained inconclusive. The present cross-sectional survey compared the diagnostic performance of the KK technique and the POC-CCA test in diagnosing S. mansoni infection in an adult population co-infected with HIV-1 in northwestern Tanzania. Methods: Single urine and stool samples from 979 adults were screened for S. mansoni infection using both the KK technique and POC-CCA tests. To compare the performance of the two diagnostic tests a combined artificial gold standard was created, based on either an egg-positive KK technique or a POC-CCA-positive test. Results: Based on the KK technique, the prevalence of S. mansoni was 47.3% (463/979, 95% CI: 44.2–50.4), as compared to 60.5% by the POC-CCA test (592/979; 95% CI: 57.4–63.5). The overall sensitivity and specificity of the POC-CCA test were 92.5% (95% CI: 89.4–94.9) and 73.3% (95% CI: 69.6–76.8), respectively. In the HIV-1 seropositive group, the sensitivity and specificity of the POC-CCA test were 78.1% (95% CI: 60.0–90.7) and 45.9% (95% CI: 35.8–56.3). Using a combined gold standard, the sensitivity of the POC-CCA test increased to >90% in both subgroups whereas that of the KK technique in the HIV-1 seropositive group was low (49.5%; 95% CI: 39.6–59.5). Conclusion: In the presence of HIV-1 co-infection, the KK technique attained a very low sensitivity. The POC-CCA test offers the best option for the rapid screening of S. mansoni infection in communities with a high prevalence of HIV-1 infection.
Item type: RESEARCH ARTICLES
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Status Barcode
RESEARCH ARTICLES MWALIMU NYERERE LEARNING RESOURCES CENTRE-CUHAS BUGANDO NFIC -1 RA0511
Total holds: 0

Abstract

Background: The diagnostic performance of the Kato Katz (KK) technique and the point-of-care circulating cathodic antigen (POC-CCA) test in detecting S. mansoni infection in the presence of the human immunodeficiency virus-1 (HIV-1) infection has remained inconclusive. The present cross-sectional survey compared the diagnostic performance of the KK technique and the POC-CCA test in diagnosing S. mansoni infection in an adult population co-infected with HIV-1 in northwestern Tanzania.

Methods: Single urine and stool samples from 979 adults were screened for S. mansoni infection using both the KK technique and POC-CCA tests. To compare the performance of the two diagnostic tests a combined artificial gold standard was created, based on either an egg-positive KK technique or a POC-CCA-positive test.

Results: Based on the KK technique, the prevalence of S. mansoni was 47.3% (463/979, 95% CI: 44.2–50.4), as compared to 60.5% by the POC-CCA test (592/979; 95% CI: 57.4–63.5). The overall sensitivity and specificity of the POC-CCA test were 92.5% (95% CI: 89.4–94.9) and 73.3% (95% CI: 69.6–76.8), respectively. In the HIV-1 seropositive group, the sensitivity and specificity of the POC-CCA test were 78.1% (95% CI: 60.0–90.7) and 45.9% (95% CI: 35.8–56.3). Using a combined gold standard, the sensitivity of the POC-CCA test increased to >90% in both subgroups whereas that of the KK technique in the HIV-1 seropositive group was low (49.5%; 95% CI: 39.6–59.5).

Conclusion: In the presence of HIV-1 co-infection, the KK technique attained a very low sensitivity. The POC-CCA test offers the best option for the rapid screening of S. mansoni infection in communities with a high prevalence of HIV-1 infection.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Catholic University of  Health and Allied Sciences - CUHAS
Directorate of ICT @ 2024