Entrance surface air kerma to patients during digital radiographic examinations in Tanzania (Record no. 28037)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02291nam a22004217a 4500 |
001 - CONTROL NUMBER | |
control field | 20240610171113.0 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | 20240610171113.0 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20240610172202.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 240610b |||||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
International Standard Serial Number | Online ISSN 1742-3406 |
040 ## - CATALOGING SOURCE | |
Transcribing agency | ddc |
041 ## - LANGUAGE CODE | |
Language code of text/sound track or separate title | English |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Fuller form of name | Atumaini Makoba |
245 ## - TITLE STATEMENT | |
Title | Entrance surface air kerma to patients during digital radiographic examinations in Tanzania |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Mwanza, Tanzania : |
Name of publisher, distributor, etc. | Catholic University of Health and Allied Sciences [CUHAS-Bugando] : |
Date of publication, distribution, etc. | 2023 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | Pages 229–239 |
Extent | Includes References |
490 ## - SERIES STATEMENT | |
Volume/sequential designation | Radiation Protection Dosimetry, Volume 200, Issue 3, March 2024 |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Abstract :<br/><br/>The aim of this study was to determine the entrance surface air kerma (ESAK) in adult patients during digital radiography and to evaluate the optimisation potential in five common X-ray examinations in Tanzania. Based on a sample of 240–610 patients, ESAK was estimated using X-ray tube output measurements, patient information and backscatter factors. The results show that the mean ESAK values were higher or comparable to data from the literature. The diagnostic reference values of ESAK for digital radiography were 0.31 mGy (chest PA), 4 mGy (lumbar spine AP), 5.4 mGy (lumbar spine LAT), 3.8 mGy (abdomen AP) and 2.4 mGy (pelvis AP). For computed radiography, the mean ESAK ranges were 0.44–0.57 mGy (thoracic AP), 3.59–3.72 mGy (lumbar spine AP), 6.16–6.35 mGy (lumbar spine LAT), 3.89–3.44 mGy (abdominal AP) and 2.92–3.47 mGy (pelvic AP). In conclusion, high ESAK variations show the potential for optimising protection in digital radiology. |
600 ## - SUBJECT ADDED ENTRY--PERSONAL NAME | |
General subdivision | Digital radiographic |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Fuller form of name | Ahmed Jusabani |
Fuller form of name | Adam Nakembetwa |
Fuller form of name | Wilson Ngoye |
Fuller form of name | Vitus Balobegwa |
Fuller form of name | Ali Masoud |
Fuller form of name | Alex Muhulo |
Fuller form of name | Huruma Mammba |
Fuller form of name | Miguta Ngulimi |
Fuller form of name | Erick Onoka |
Fuller form of name | Haika Maro |
Fuller form of name | Hilda Makungu |
Fuller form of name | Musa Ndukeki |
Fuller form of name | Abdallah Kileo |
Fuller form of name | Wilbroad Muhogora |
Fuller form of name | Ahmed Jusabani |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href=" https://doi.org/10.1093/rpd/ncad294"> https://doi.org/10.1093/rpd/ncad294</a> |
Link text | https://doi.org/10.1093/rpd/ncad294 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | ddc |
Koha item type | RESEARCH ARTICLES |
Suppress in OPAC |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Date acquired | Total checkouts | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|
MWALIMU NYERERE LEARNING RESOURCES CENTRE-CUHAS BUGANDO | MWALIMU NYERERE LEARNING RESOURCES CENTRE-CUHAS BUGANDO | 06/10/2024 | 20240610171113.0 | 06/10/2024 | 06/10/2024 | RESEARCH ARTICLES |