Entrance surface air kerma to patients during digital radiographic examinations in Tanzania (Record no. 28037)

MARC details
000 -LEADER
fixed length control field 02291nam a22004217a 4500
001 - CONTROL NUMBER
control field 20240610171113.0
003 - CONTROL NUMBER IDENTIFIER
control field 20240610171113.0
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240610172202.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240610b |||||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number Online ISSN 1742-3406
040 ## - CATALOGING SOURCE
Transcribing agency ddc
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title English
100 ## - MAIN ENTRY--PERSONAL NAME
Fuller form of name Atumaini Makoba
245 ## - TITLE STATEMENT
Title Entrance surface air kerma to patients during digital radiographic examinations in Tanzania
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Mwanza, Tanzania :
Name of publisher, distributor, etc. Catholic University of Health and Allied Sciences [CUHAS-Bugando] :
Date of publication, distribution, etc. 2023
300 ## - PHYSICAL DESCRIPTION
Extent Pages 229–239
Extent Includes References
490 ## - SERIES STATEMENT
Volume/sequential designation Radiation Protection Dosimetry, Volume 200, Issue 3, March 2024
520 ## - SUMMARY, ETC.
Summary, etc. Abstract :<br/><br/>The aim of this study was to determine the entrance surface air kerma (ESAK) in adult patients during digital radiography and to evaluate the optimisation potential in five common X-ray examinations in Tanzania. Based on a sample of 240–610 patients, ESAK was estimated using X-ray tube output measurements, patient information and backscatter factors. The results show that the mean ESAK values were higher or comparable to data from the literature. The diagnostic reference values of ESAK for digital radiography were 0.31 mGy (chest PA), 4 mGy (lumbar spine AP), 5.4 mGy (lumbar spine LAT), 3.8 mGy (abdomen AP) and 2.4 mGy (pelvis AP). For computed radiography, the mean ESAK ranges were 0.44–0.57 mGy (thoracic AP), 3.59–3.72 mGy (lumbar spine AP), 6.16–6.35 mGy (lumbar spine LAT), 3.89–3.44 mGy (abdominal AP) and 2.92–3.47 mGy (pelvic AP). In conclusion, high ESAK variations show the potential for optimising protection in digital radiology.
600 ## - SUBJECT ADDED ENTRY--PERSONAL NAME
General subdivision Digital radiographic
700 ## - ADDED ENTRY--PERSONAL NAME
Fuller form of name Ahmed Jusabani
Fuller form of name Adam Nakembetwa
Fuller form of name Wilson Ngoye
Fuller form of name Vitus Balobegwa
Fuller form of name Ali Masoud
Fuller form of name Alex Muhulo
Fuller form of name Huruma Mammba
Fuller form of name Miguta Ngulimi
Fuller form of name Erick Onoka
Fuller form of name Haika Maro
Fuller form of name Hilda Makungu
Fuller form of name Musa Ndukeki
Fuller form of name Abdallah Kileo
Fuller form of name Wilbroad Muhogora
Fuller form of name Ahmed Jusabani
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href=" https://doi.org/10.1093/rpd/ncad294"> https://doi.org/10.1093/rpd/ncad294</a>
Link text https://doi.org/10.1093/rpd/ncad294
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme ddc
Koha item type RESEARCH ARTICLES
Suppress in OPAC
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total checkouts Barcode Date last seen Price effective from Koha item type
          MWALIMU NYERERE LEARNING RESOURCES CENTRE-CUHAS BUGANDO MWALIMU NYERERE LEARNING RESOURCES CENTRE-CUHAS BUGANDO 06/10/2024   20240610171113.0 06/10/2024 06/10/2024 RESEARCH ARTICLES
Catholic University of  Health and Allied Sciences - CUHAS
Directorate of ICT @ 2024